Medium Voltage Switchgear Manufacturer

Zoliov delivers reliable and high-performance medium voltage switchgear solutions for power distribution, industrial facilities, and infrastructure projects worldwide, ensuring safety, efficiency, and long service life.

What is Medium Voltage Switchgear?

Medium voltage switchgear refers to electrical equipment designed to control, protect, and isolate power distribution systems operating typically between 1 kV and 36 kV. It plays a crucial role in ensuring safe and reliable power flow, enabling operators to manage circuits efficiently and protect electrical infrastructure from faults.

Main application scenarios

  • Power plant outgoing line switch stations

  • Transmission and distribution substations

  • Industrial power distribution systems

  • Urban grid distribution centers

  • Renewable energy grid connection points

Medium voltage switchgear is essential for stable power supply, efficient control, and system protection in both conventional and new energy networks.

Medium Volume Switchgear

Zoliov — Your Reliable Medium Voltage Switchgear Manufacturer

point one

Strong Technical Expertise

With over 20 years of professional manufacturing experience, Zoliov has mastered core switchgear technologies and provides complete solutions across the 1 kV–36 kV range. Our dedicated R&D team continuously innovates to keep our products at the forefront of the medium voltage industry.

point two

Strict Quality Assurance System

We are certified to ISO9001 and ISO14001, and fully comply with international standards such as IEC and GB. Each medium voltage switchgear unit undergoes rigorous type testing and factory inspection to guarantee outstanding performance and reliability.

point three

Customized Engineering Services

We offer tailored design solutions based on each project’s technical parameters and on-site conditions. From system planning and engineering design to installation and commissioning, Zoliov provides end-to-end technical support to meet the complex requirements of global power distribution projects.

FEATURED PRODUCTS

Featured Medium Voltage Switchgear Products

Explore our medium voltage switchgear series, designed for flexible configuration and reliable operation.
All products can be customized to match your specific technical specifications.
We offer one-stop services — from design and manufacturing to installation and commissioning — ensuring every project is delivered smoothly and successfully.

XGN66-12(Z) Fixed Metal-Enclosed Switchgear
XGN66-12(Z) Fixed Metal-Enclosed Switchgear

Medium Voltage Switchgear XGN66-12(Z) Fixed Metal-Enclosed Switchgear The XGN66-12(Z) is our latest medium voltage switchgear...

XGN2-12 Compact Metal-Enclosed Switchgear
XGN2-12 Compact Metal-Enclosed Switchgear

Medium Voltage Switchgear XGN2-12 Compact Metal-Enclosed Switchgear XGN2-12 box-type fixed AC metal-enclosed switchgear is suitable...

TBBZ Series Medium Voltage Reactive Power Compensation Switchgear
TBBZ Series Medium Voltage Reactive Power Compensation Switchgear
TBBZ Medium-voltage reactive power compensation switchgear for 6kV–12kV systems, supporting power factor correction, voltage stabilization,...
KYN61-40.5(Z) Armored Withdrawable Type AC Metal-Enclosed Switchgear
KYN61-40.5(Z) Armored Withdrawable Type AC Metal-Enclosed Switchgear

Medium Voltage Switchgear KYN61-40.5(Z) Armored Withdrawable Type AC Metal-Enclosed Switchgear The KYN61-40.5(Z) armored withdrawable type...

KYN28A-12 AC Metal-Enclosed Switchgear
KYN28A-12(GZS1) Armored Withdrawable Type AC Metal-Enclosed Switchgear

Medium Voltage Switchgear KYN28A-12(GZS1) Armored Withdrawable Type AC Metal-Enclosed Switchgear KYN28A-12(GZS1) Armored Withdrawable Type AC...

Why Choose Zoliov as Your Medium Voltage Switchgear Manufacturer?

Advanced Manufacturing Capacity

Zoliov operates a modern production base equipped with advanced international machinery and processes. With an annual capacity exceeding 1,000 sets of medium voltage switchgear, we can meet large-scale project demands while ensuring stable quality and on-time delivery.

Authoritative Certifications

We are certified to ISO9001 and ISO14001, and fully comply with international standards such as IEC and GB. Each medium voltage switchgear unit undergoes rigorous type testing and factory inspection to guarantee outstanding performance and reliability.

Comprehensive Technical Support

Our experienced engineering team provides end-to-end technical services, including system design, product selection, installation, and commissioning. With 24/7 technical support and fast response times, we ensure each project runs smoothly from start to finish.

Global Projects

America, Nevada, PV project

China, Beijing Daxing Airport

Vietnam, Hanoi,Biopharmaceutical Plant

Power distribution system for enterprises in the Philippines

Brazil, wind-solar hybrid complex

UAE, Shams Power Plant Project

Zimbabwe, 132KV transmission and distribution system

Malaysia, Penang, Semiconductor Industrial Zone

CUSTOMIZED SERVICE STEPS

Customer request
Submit parameters and drawings
Determine parameters and drawings
Offer according to drawings
Sign contract
Material procurement and production
Test and quality inspection
Inspection and delivery

Medium Voltage Switchgear Technical Resources

To help engineers and purchasing decision-makers better understand the technical features of medium voltage switchgear, we’ve compiled a series of professional articles covering selection guidelines, technical comparisons, and key application insights.

Frequently Asked Questions

Main components of a typical MV switchgear panel

A standard MV switchgear panel is typically divided into several isolated compartments for safety and reliability:

  1. Circuit Breaker Compartment: Houses the core switching device, most commonly a Vacuum Circuit Breaker (VCB). It is often a withdrawable “trolley” or “cassette” design for easy maintenance and replacement.
  2. Busbar Compartment: Contains the main busbars that run horizontally across a lineup of switchgear panels, used to collect and distribute electrical power.
  3. Cable Compartment: Where the incoming or outgoing power cables are terminated. It also typically contains Current Transformers (CTs), an earthing switch, and surge arresters.
  4. Low Voltage / Instrument Compartment: Houses all the secondary equipment, such as protective relays, meters, control switches, indicator lamps, and PLCs. It is completely segregated from the high-voltage sections for operator safety.
  5. Instrument Transformers: Includes Current Transformers (CTs), located in the cable compartment, and Potential Transformers (PTs/VTs), which may be in the busbar or cable compartment. They provide the necessary signals for protection and measurement devices.
Common applications of medium voltage switchgear
  • Utility Power Distribution: Used in urban and rural substations to take power from the high-voltage transmission grid, step it down, and distribute it through various feeder lines to residential, commercial, and industrial customers.
  • Industrial Facilities: Serves as the power heart of heavy industries (e.g., steel, petrochemicals, automotive) to control and protect high-power motors, furnaces, pumps, and compressors.
  • Renewable Energy: In wind farms and solar PV plants, it is used to collect the power generated by multiple turbines or inverters and safely connect it to the utility grid.
  • Large Commercial Buildings & Data Centers: Used as the main service entrance equipment to receive power from the grid and distribute it to various step-down transformers throughout the building, feeding critical loads like HVAC, elevators, and servers.
  • Infrastructure: Provides reliable power distribution and protection for critical transportation hubs such as airports, seaports, and rail/subway systems.
Factors to consider when selecting MV switchgear
  • Electrical Ratings:
    • Rated Voltage: Must match the system voltage.
    • Rated Current: The current rating of the busbars and circuit breakers must meet the maximum load demand.
    • Short Circuit Rating: The rated short-circuit breaking current (kA) and short-time withstand current (kA/s) must be greater than the system’s prospective fault level.
  • Insulation Type:
    • Air-Insulated Switchgear (AIS): Lower cost and mature technology, but has a large footprint.
    • Gas-Insulated Switchgear (GIS): Very compact, highly reliable, and virtually maintenance-free, but has a higher initial cost.
  • Safety & Design:
    • Internal Arc Classification (IAC): A critical safety feature indicating the switchgear’s ability to protect personnel in the event of an internal arc fault.
    • Compartmentalization: A Metal-Clad design offers the highest level of safety and reliability by segregating primary components in separate, grounded metal compartments.
  • Physical Conditions:
    • Footprint: The dimensional constraints of the installation space.
    • Environmental Conditions: Indoor vs. outdoor installation, altitude, temperature, humidity, and pollution levels.
  • Standards & Compliance:
    • Must comply with international (IEC) or regional (ANSI/IEEE) standards, such as IEC 62271-200.
Comparison of AIS and GIS for medium voltage
Feature Air-Insulated Switchgear (AIS) Gas-Insulated Switchgear (GIS)
Insulating Medium Air SF6 Gas
Footprint Large Very Compact, approx. 30-40% of AIS
Installation Site Spacious indoor or outdoor substations Space-limited urban buildings, basements, offshore platforms
Environmental Immunity Higher sensitivity to dust, humidity, altitude Extremely low, all live parts are sealed, immune to external conditions
Maintenance Higher, requires regular cleaning of insulators Extremely low, virtually maintenance-free
Safety Exposed busbars can pose a risk; relies on clearance Fully enclosed and grounded metal tank offers maximum safety
Installation Relatively simple on-site assembly Complex; requires special equipment for gas handling
Initial Cost Lower Higher
What are the main protection schemes in MV switchgear?

The protective relay in MV switchgear is the “brain” that detects faults and commands the circuit breaker to trip. The main protection schemes (identified by ANSI standard device numbers) include:

  • Overcurrent Protection (50/51): The most fundamental protection. It detects current exceeding normal values. 51 is time-delayed overcurrent (for overloads), and 50 is instantaneous overcurrent (for short circuits).
  • Earth Fault Protection (50N/51N): Detects fault current flowing to ground. This is critical for personnel safety and fire prevention.
  • Differential Protection (87): A high-speed, selective protection for important assets like transformers (87T) or motors (87M). It operates by comparing the current entering and leaving the asset; a difference indicates an internal fault.
  • Under/Over Voltage Protection (27/59): Protects equipment from damage when the system voltage deviates from its normal operating range.
  • Motor Protection: Specialized relays provide comprehensive protection for motors, including thermal overload (49) and phase unbalance/negative sequence (46), to prevent overheating, stalling, etc.
Medium voltage switchgear standards
  • ✅ IEC 62271-200: The most important international standard for metal-enclosed MV switchgear. It specifies design, construction, performance tests, and safety requirements, including the Internal Arc Classification (IAC).
  • ✅ IEC 62271-1: The common specifications for all high and medium voltage switchgear.
  • ✅ IEC 62271-100: The specific standard for AC circuit breakers.
  • ✅ ANSI/IEEE C37 Series: The widely used suite of standards in North America. For example:
    • C37.20.2: Standard for Metal-Clad Switchgear.
    • C37.04, C37.06, C37.09: Standards for rating, testing, and application of circuit breakers.
  • ✅ UL/cUL Certification: In North America, many switchgear assemblies require UL listing to certify compliance with specific safety and construction standards.
Medium voltage switchgear maintenance procedures

WARNING: All maintenance must be performed by qualified personnel after the equipment is fully de-energized, grounded, and Lockout-Tagout (LOTO) procedures are applied.

  1. Cleaning: Use a vacuum and dry cloths to clean the interior of all compartments, especially insulators, busbar supports, and breaker surfaces, to prevent flashovers caused by dust accumulation.
  2. Inspection & Tightening:
    • Visually inspect all components for damage, corrosion, or signs of overheating.
    • Use a calibrated torque wrench to check and tighten all busbar and cable connection bolts.
    • Perform thermographic (infrared) scans during operation to identify hot spots.
  3. Circuit Breaker Maintenance:
    • Rack out the circuit breaker to the test/disconnected position.
    • Clean and lubricate the operating mechanism according to the manufacturer’s recommendations.
    • Perform manual and electrical open/close operation tests.
    • Test the integrity of the vacuum interrupters (requires special equipment).
  4. Protection System Testing:
    • Using a relay test set, perform secondary injection tests on the protective relays to verify their settings and operating times.
  5. Auxiliary Equipment Check:
    • Check that space heaters and ventilation systems are working correctly to prevent condensation.
    • Verify the function of all indicator lights, meters, and control switches.
Basic operation of a circuit breaker in MV switchgear

(Scene: Operating a withdrawable vacuum circuit breaker)

  1. Charging the Spring: “Most MV circuit breakers use a stored-energy spring mechanism. We can charge it automatically with a motor or, if control power is off, manually by inserting this handle. When this indicator shows ‘Charged,’ the breaker is ready to be closed.”
  2. Racking In: “With the breaker in the ‘Open’ position, we use the racking handle to move the trolley from the ‘Test/Disconnected’ position to the ‘Service’ position, fully engaging the primary and secondary control plugs.”
  3. Closing the Breaker: “Now, either locally or remotely, we push the ‘Close’ button. The charged spring releases its energy, driving the mechanism to rapidly close the breaker’s main contacts.”
  4. Opening/Tripping: “When a trip signal is received from a protective relay or the ‘Open’ button is pressed, the trip coil is energized. This releases the latching mechanism, and another set of springs rapidly opens the main contacts, extinguishing the arc.”
Medium voltage switchgear troubleshooting guide
Problem Possible Cause Solution
Breaker fails to close 1. Loss of control power.
2. Closing spring is not charged.
3. Protective relay is in lockout/tripped state.
4. Breaker is not in the service or test position.
1. Check control fuses or MCBs.
2. Check charging motor or charge manually.
3. Reset the protective relay.
4. Rack the breaker to the correct position.
Breaker trips immediately after closing 1. A permanent fault exists on the line.
2. Incorrect relay settings or faulty relay.
3. Fault in the breaker’s “a” contact (seal-in) circuit.
1. Isolate and investigate the line for the fault.
2. Verify relay settings and test the relay.
3. Check the breaker’s auxiliary contacts and associated wiring.
Fails to operate remotely 1. Local/Remote selector switch is in “Local.”
2. Issue with communication or control cables.
3. Fault in the PLC or RTU control system.
1. Turn the selector switch to “Remote.”
2. Check the continuity of the control cables.
3. Diagnose and repair the control system.
Arc flash protection in medium voltage switchgear

Background: A data center needed to ensure the highest level of safety for its power system to prevent an arc flash incident, which could cause severe injury and catastrophic equipment damage.

Advanced Protection Measures Adopted:

  1. Use of Arc-Resistant Switchgear: They selected switchgear compliant with IEC 62271-200, Classification IAC A-FLR. This design includes a reinforced enclosure, robust door latches, and a special exhaust plenum. In an arc fault, the explosive high-pressure gases are safely channeled away through the top plenum, protecting personnel standing at the Front, Lateral, and Rear of the gear.
  2. Installation of an Active Arc Flash Detection System: Fiber-optic arc sensors were installed in each switchgear compartment. This system simultaneously detects the bright light of an arc and the associated fault current. When both conditions are met, it sends an ultra-fast trip command to the breaker within 1-2 milliseconds.
  3. Implementation of Remote Operation: All breaker operations (opening, closing, racking in/out) can be performed from a safe distance in a control room via a remote interface. This “zero-contact” operation fundamentally eliminates operator exposure to the hazard.

Result: Through this combination of measures, the data center’s arc flash incident energy was reduced to extremely low levels, drastically improving the safety of maintenance personnel and ensuring the continuity of their critical power supply.

Contact Zoliov to Start Your Cooperation Journey

As a professional medium voltage switchgear manufacturer, Zoliov has always taken technological innovation as our driving force and customer needs as our focus. We are dedicated to providing high-quality products and dependable services for power distribution projects around the world. We deeply understand the importance of each project and are committed to becoming your most reliable long-term partner.

Whether you are a substation engineer, equipment procurement manager, or project decision-maker, our team will offer professional technical consultation, tailored solutions, and full-process support. Let’s join hands to advance power distribution technology and create greater value together.

Neutral Earthing Resistor (NER): Definition, Purpose & Applications

Join the Future of Power Distribution

Ready to Upgrade Your Electrical Infrastructure?

Don’t let outdated switchgear compromise your operations. Experience the reliability and innovation of Zoliov’s switchgear solutions—where safety meets advanced engineering.