Oil-Immersed Transformers Manufacturer

Oil-Immersed Transformers Manufacturer

Zoliov provides high-quality and reliable oil-immersed transformers for power distribution networks, industrial facilities, and infrastructure projects worldwide. Our transformers ensure efficient cooling, stable performance, and long service life, even under demanding operating conditions.

What are Oil-Immersed Transformers?

Oil-immersed transformers are electrical power devices that use transformer oil for cooling and insulation. They consist of a core, windings, oil tank, and radiators, ensuring efficient heat dissipation and reliable operation.
Commonly used in power distribution and transmission systems (10 kV – 220 kV), they offer high efficiency, excellent insulation performance, and long service life, making them ideal for both industrial and utility applications.

Main application scenarios

  • Power transmission and distribution systems – providing stable voltage transformation and reliable operation

  • Industrial and manufacturing facilities – supporting continuous and efficient power supply for heavy equipment

  • Renewable energy integration – connecting solar and wind power to medium and high-voltage grids

  • Urban infrastructure and commercial complexes – ensuring safe and stable power distribution

  • Substations and distribution centers – acting as critical nodes for network efficiency and protection

Oil-immersed transformers play a vital role in power reliability, grid stability, and energy efficiency, making them essential components in modern power systems.

Oil-Immersed Transformers

Zoliov — Your Reliable Oil-Immersed Transformers Manufacturer

point one

Strong Technical Expertise

With over 20 years of transformer manufacturing experience, Zoliov has developed advanced capabilities in oil-immersed transformer design, insulation technology, and thermal management. Our engineering team focuses on optimizing efficiency, reliability, and service life, ensuring stable operation under demanding grid and industrial conditions.

point two

Strict Quality Assurance System

Zoliov’s production facilities are certified to ISO9001 and ISO14001, and all oil-immersed transformers comply with IEC and GB standards. Each unit undergoes rigorous type testing, insulation performance verification, and factory inspections to guarantee long-term reliability and safety in the field.

point three

Customized Engineering Solutions

We provide tailor-made transformer solutions to meet different voltage levels, capacities, and environmental conditions. From conceptual design and technical consultation to manufacturing and installation, Zoliov offers end-to-end support for complex utility and industrial power projects.

FEATURED PRODUCTS

Featured Oil-Immersed Transformers Products

Explore Zoliov’s comprehensive range of oil-immersed transformers, designed for high efficiency, excellent insulation performance, and stable operation in power distribution and transmission systems.
Our product line includes distribution transformers, step-up and step-down transformers, energy-efficient models, and special-purpose transformers for various industrial and utility applications.
All units can be custom-engineered to match different voltage levels, capacities, and environmental conditions. We offer one-stop services — from design and manufacturing to installation and commissioning — ensuring smooth and reliable project delivery.

SH15 amorphous alloy power transformer
SH15 amorphous alloy power transformer

Oil-immersed Transformer SH15 amorphous alloy power transformer The SH15 amorphous alloy power transformer is a...

35kV Oil-Immersed Transformer
33kV Oil-Immersed Transformer
33kV Oil-Immersed Transformer provides reliable voltage conversion for substations, industrial facilities, utility networks, and renewable...
10kV Oil-Immersed Transformer
11kV Oil-Immersed Transformer
Reliable 11kV oil-immersed transformer for medium-voltage distribution, outdoor use, and customized project requirements....

Why Choose Zoliov as Your Oil-Immersed Transformers Manufacturer?

Advanced Manufacturing Capacity

Zoliov operates a modern transformer production base equipped with advanced manufacturing and testing equipment. With large annual capacity, we can efficiently deliver oil-immersed transformers for domestic and international power projects, ensuring stable quality and reliable lead times for bulk orders.

Authoritative Certifications

Zoliov’s production facilities are certified to ISO9001 and ISO14001, and all oil-immersed transformers comply with IEC and GB standards. Each unit undergoes rigorous type testing, insulation performance verification, and factory inspections to guarantee long-term reliability and safety in the field.

Comprehensive Technical Support

Our experienced engineering team provides end-to-end technical services, including transformer selection, design consultation, installation guidance, and commissioning assistance. With 24/7 technical support and fast response times, Zoliov ensures smooth implementation for complex utility and industrial power projects.

Global Projects

America, Nevada, PV project

China, Beijing Daxing Airport

Vietnam, Hanoi,Biopharmaceutical Plant

Power distribution system for enterprises in the Philippines

Brazil, wind-solar hybrid complex

UAE, Shams Power Plant Project

Zimbabwe, 132KV transmission and distribution system

Malaysia, Penang, Semiconductor Industrial Zone

CUSTOMIZED SERVICE STEPS

Customer request
Submit parameters and drawings
Determine parameters and drawings
Offer according to drawings
Sign contract
Material procurement and production
Test and quality inspection
Inspection and delivery

Oil-Immersed Transformers Technical Resources

To help engineers and procurement decision-makers better understand the technical features of oil-immersed transformers, we’ve prepared a series of professional articles covering selection guidelines, structural comparisons, and application insights to support your project design and purchasing decisions.

Frequently Asked Questions

What is an oil-immersed transformer?

An oil-immersed transformer is a type of electrical transformer where the main core and windings are completely submerged in a tank filled with insulating mineral oil. This oil, commonly known as transformer oil, serves two primary functions: it acts as a superior electrical insulator to prevent short circuits inside the tank, and it serves as a coolant to dissipate the significant amount of heat generated during operation. They are the most common type of transformer used in high-voltage and high-power applications, such as utility substations and large industrial plants.

How does an oil-immersed transformer work?

An oil-immersed transformer works on the principle of electromagnetic induction, with the oil playing a critical role in its operation:

  1. Electromagnetic Induction: Just like any transformer, an alternating current in the primary winding creates a changing magnetic field in the iron core. This field then induces a voltage in the secondary winding.
  2. Cooling Function: As current flows through the windings, heat is generated (known as I²R losses). The surrounding transformer oil absorbs this heat. The heated oil becomes less dense and rises, creating a natural convection current that transfers the heat to the transformer tank walls and radiators. The heat is then dissipated into the surrounding atmosphere.
  3. Insulation Function: The transformer oil has a high dielectric strength, meaning it is a very poor conductor of electricity. By filling all the gaps between the windings, core, and tank, it provides comprehensive insulation, preventing electrical arcing and faults at high voltages.
What are the key parts of an oil-immersed transformer?

While sharing basic components with all transformers, oil-immersed units have several unique and critical parts related to the oil system:

  1. Core and Windings: The active part where the voltage transformation takes place.
  2. Main Tank: The sealed steel tank containing the core, windings, and oil.
  3. Transformer Oil: The mineral oil used for insulation and cooling.
  4. Radiators: External fins or tubes that provide a large surface area to cool the oil.
  5. Conservator Tank: A smaller expansion tank mounted above the main tank that allows the oil to expand and contract with temperature changes without exposing it to atmospheric moisture.
  6. Buchholz Relay: A critical safety device located in the pipe between the main tank and the conservator, which detects gas accumulation or oil surges indicating an internal fault.
  7. Breather: A device connected to the conservator that contains silica gel. It allows the transformer to “breathe” as the oil level changes but dries the incoming air to prevent moisture from contaminating the oil.
  8. Bushings: Insulated terminals that allow the HV and LV conductors to connect to the internal windings safely through the tank wall.
  9. Pressure Relief Device (PRD): A safety valve that rapidly releases excess pressure from the tank during a severe internal fault to prevent a tank rupture.
What's the difference between a dry-type and an oil-immersed transformer?

This is a fundamental choice based on the application and location.

Feature Oil-Immersed Transformer Dry-Type Transformer
Cooling/Insulation Uses mineral oil. Uses air and solid cast resin or VPI insulation.
Fire Safety Lower. The oil is flammable, requiring fire suppression systems and containment pits. Highest. No flammable liquids, making it the safest choice for indoor use.
Location Primarily used outdoors in substations and industrial yards. Primarily used indoors: in commercial buildings, hospitals, tunnels, and data centers.
Efficiency & Overload More efficient and has a better short-term overload capability. Less efficient and has lower overload tolerance.
Size & Weight More compact and lighter for the same power rating. Larger and heavier for the same power rating.
Maintenance Requires regular oil testing and maintenance of gaskets and cooling systems. Requires minimal maintenance (mostly cleaning).
Cost Generally has a lower initial purchase price. Generally has a higher initial purchase price.
What are the main advantages of an oil-filled transformer?

Oil-filled transformers are the preferred choice for most utility and large-scale applications due to several key advantages:

  • Superior Cooling: Oil is a much more effective cooling medium than air, allowing for higher efficiency and more compact designs for a given power rating.
  • Higher Overload Capability: The thermal mass of the oil allows the transformer to handle short-term overloads better than a dry-type unit.
  • Longer Lifespan: A well-maintained, sealed oil-immersed transformer has a very long service life, often exceeding 30-40 years.
  • Cost-Effectiveness: For high kVA and MVA ratings, oil-immersed transformers offer a significantly lower initial purchase cost compared to dry-type alternatives.
  • Diagnostic Capability: The oil itself acts as a diagnostic tool. By analyzing dissolved gases in the oil (DGA), engineers can detect incipient faults long before they become catastrophic failures.
What are the critical safety measures for oil-immersed transformers?

Due to the large volume of flammable oil, safety is a primary concern. Critical safety measures include:

  • Oil Containment (Bund): Installing the transformer within a concrete containment pit or bund that can hold at least 110% of the transformer’s total oil volume in case of a leak or tank rupture.
  • Fire Protection Systems: For critical indoor or high-risk installations, this includes deluge water spray systems or nitrogen injection systems that activate in response to high temperatures or fire.
  • Properly Functioning Protection Relays: Ensuring that devices like the Buchholz relay, pressure relief device (PRD), and temperature sensors are correctly calibrated and operational.
  • Regular Inspections: Periodically checking for oil leaks, especially around gaskets, bushings, and radiator connections.
  • Clearance: Maintaining adequate clearance around the transformer, free from combustible materials.
Where are oil-immersed transformers typically used?

Their high efficiency and robustness make them ideal for medium to large-scale power applications. You will typically find them in:

  • Power Generation Stations: As Generator Step-Up (GSU) transformers.
  • Transmission and Distribution Substations: The most common application for managing power flow across the grid.
  • Large Industrial Facilities: Powering heavy industrial processes, smelters, and large motor loads.
  • Renewable Energy Projects: At collector substations for large wind and solar farms.
  • Any high-power outdoor application where fire risk can be managed effectively.
What is a typical maintenance schedule for an oil-immersed transformer?

A proactive maintenance schedule is key to a long service life.

  • Daily/Weekly Checks:
    • Visual inspection for oil leaks.
    • Check the oil level indicator on the conservator tank.
    • Note the oil temperature and winding temperature readings.
  • Annual Maintenance:
    • Take an oil sample for Dissolved Gas Analysis (DGA) and a full quality screen (moisture, dielectric strength).
    • Clean porcelain bushings.
    • Clean radiator fins to ensure efficient cooling.
    • Inspect the silica gel in the breather and replace if it has changed color (from blue to pink/white).
  • Every 5-7 Years (or as needed based on oil analysis):
    • Perform a comprehensive suite of electrical tests (insulation resistance, winding resistance, turns ratio).
    • Service the on-load tap changer (OLTC).
    • Consider oil filtration or regeneration if oil quality has degraded.
What should you inspect when a new oil-immersed transformer arrives on site?

Receiving inspection is critical to ensure no damage occurred during transport.

  1. Check for Physical Damage: Carefully inspect the tank, radiators, bushings, and all accessories for any dents, broken parts, or signs of impact.
  2. Check for Leaks: Thoroughly inspect all gaskets, welds, and fittings for any signs of oil leakage.
  3. Verify Oil Level: Check the magnetic oil gauge (MOG) on the conservator to ensure the oil level is correct for the ambient temperature.
  4. Inspect the Pressure Relief Device (PRD): Ensure the indicator flag on the PRD has not popped up, which would indicate high pressure during transit.
  5. Check the Nameplate: Verify that all data on the manufacturer’s nameplate (kVA, voltages, vector group, etc.) matches the purchase order and technical specifications.
  6. Review Shipping Recorders: If impact recorders were fitted for shipping, check their readings to see if the unit experienced any excessive shocks.
What is a conservator tank and why is it important for an oil-filled transformer?

A conservator tank is a smaller cylindrical expansion tank mounted on top of the transformer’s main tank. Its purpose is to accommodate the thermal expansion and contraction of the transformer oil.

As the transformer heats up under load, the oil expands and its volume increases. This excess oil flows up into the conservator. When the transformer cools, the oil contracts, and oil from the conservator flows back into the main tank. This system ensures the main tank remains completely filled with oil at all times, which is critical for proper insulation. Crucially, it minimizes the oil’s contact with the atmosphere, reducing the risk of oxidation and moisture contamination.

Contact Zoliov to Start Your Cooperation Journey

As a professional oil-immersed transformers manufacturer, Zoliov is committed to technological innovation and customer-oriented service, providing reliable products and solutions for power distribution and transmission projects worldwide. We understand the importance of every project and aim to become your most trusted long-term partner.

Whether you are a power grid engineer, procurement manager, or project decision-maker, our team offers expert consultation, customized transformer solutions, and end-to-end technical support — from product selection to installation and commissioning.
Let’s work together to build safer, more efficient, and more reliable power systems.

Neutral Earthing Resistor (NER): Definition, Purpose & Applications

Join the Future of Power Distribution

Ready to Upgrade Your Electrical Infrastructure?

Don’t let outdated switchgear compromise your operations. Experience the reliability and innovation of Zoliov’s switchgear solutions—where safety meets advanced engineering.