Compact Substation

Power Transformer Manufacturer

Zoliov provides high-quality and reliable power transformer solutions for transmission networks, industrial facilities, and infrastructure projects worldwide. Our transformers are designed to ensure efficient energy conversion,stable performance, and long-term operational reliability in demanding power systems.

What is a Power Transformer?

A power transformer is an electrical device used to transfer and regulate electrical energy between different voltage levels in transmission and distribution networks. Designed for high efficiency and minimal power loss, power transformers play a critical role in stepping up or stepping down voltages, enabling safe and efficient long-distance power transmission.

Main application scenarios

  • Transmission networks – stepping up voltages for efficient long-distance power delivery

  • Distribution substations – stepping down voltages for regional power supply

  • Industrial facilities – supporting high-load equipment and stable power supply

  • Renewable energy projects – integrating solar and wind power into the grid

  • Infrastructure developments – ensuring stable voltage levels for utilities and transportation

Power transformers are essential for voltage regulation, energy efficiency, and system reliability in both traditional and renewable power networks.

Power Transformer

Zoliov — Your Reliable Power Transformer Manufacturer

point one

Strong Technical Expertise

With over 20 years of transformer manufacturing experience, Zoliov has developed advanced expertise in power transformer design, winding technology, and insulation systems. We provide solutions engineered for high efficiency, reliability, and compliance with international standards.

point two

Strict Quality Assurance System

Our production processes are certified to ISO9001 and ISO14001, and fully comply with IEC and GB standards. Every power transformer undergoes type testing, load performance verification, and safety inspections to guarantee outstanding performance and long service life.

point three

Customized Engineering Services

We offer tailored transformer solutions to meet specific voltage ratings, capacity requirements, and site conditions. From system design and engineering to installation and commissioning, Zoliov provides end-to-end support for complex power projects worldwide.

FEATURED PRODUCTS

Featured Power Transformer Products

Explore Zoliov’s wide range of power transformers, designed to deliver efficient, reliable, and safe energy conversion for a variety of applications.
All transformers can be custom-engineered to match your project’s technical specifications, including voltage class, capacity, and cooling methods.
We provide one-stop services — from design and manufacturing to installation and commissioning — ensuring smooth project implementation and long-term system stability.

SH15 amorphous alloy power transformer
SH15 amorphous alloy power transformer

Oil-immersed Transformer SH15 amorphous alloy power transformer The SH15 amorphous alloy power transformer is a...

35kV Oil-Immersed Transformer
33kV Oil-Immersed Transformer
33kV Oil-Immersed Transformer provides reliable voltage conversion for substations, industrial facilities, utility networks, and renewable...
10kV Oil-Immersed Transformer
11kV Oil-Immersed Transformer
Reliable 11kV oil-immersed transformer for medium-voltage distribution, outdoor use, and customized project requirements....
SG10 Non-Encapsulated H-Class Three-Phase Dry-Type Power Transformer
SG10 Non-Encapsulated H-Class Three-Phase Dry-Type Power Transformer

Dry-type Transformer SG10 Non-Encapsulated H-Class Three-Phase Dry-Type Power Transformer The SG10 Non-Encapsulated H-Class Three-Phase Dry-Type...

SC(B)H15 Series Amorphous Alloy Dry-Type Transformers
SC(B)H15 Series Amorphous Alloy Dry-Type Transformers

Dry-type Transformer SC(B)H15 Series Amorphous Alloy Dry-Type Transformers The SC(B)H15 Series Amorphous Alloy Dry-Type Transformer...

35kV-grade dry-type transformer
33kV-grade dry-type transformer

Dry-type Transformer 33kV-grade dry-type transformer 33kV Grade Dry Type Transformer is designed to directly step...

10kV SC(B)10/11/12/13/14/18 series dry-type epoxy resin cast transformers
11KV level dry-type transformer
Safe 11kV dry-type transformer for indoor distribution, fire resistance, low noise, and low maintenance....

Why Choose Zoliov as Your Power Transformer Manufacturer?

Advanced Manufacturing Capacity

Zoliov operates a modern production facility with advanced coil winding, core assembly, and testing equipment. With large annual capacity, we meet bulk supply demands while maintaining strict quality and delivery standards.

Authoritative Certifications

Our production processes are certified to ISO9001 and ISO14001, and fully comply with IEC and GB standards. Every power transformer undergoes type testing, load performance verification, and safety inspections to guarantee outstanding performance and long service life.

Comprehensive Technical Support

Our expert team provides end-to-end engineering services, including product selection, grid integration, installation, and commissioning. With 24/7 technical support, we ensure smooth implementation and reliable performance throughout the project lifecycle.

Global Projects

America, Nevada, PV project

China, Beijing Daxing Airport

Vietnam, Hanoi,Biopharmaceutical Plant

Power distribution system for enterprises in the Philippines

Brazil, wind-solar hybrid complex

UAE, Shams Power Plant Project

Zimbabwe, 132KV transmission and distribution system

Malaysia, Penang, Semiconductor Industrial Zone

CUSTOMIZED SERVICE STEPS

Customer request
Submit parameters and drawings
Determine parameters and drawings
Offer according to drawings
Sign contract
Material procurement and production
Test and quality inspection
Inspection and delivery

Power Transformer Technical Resources

To help engineers and procurement decision-makers better understand the technical characteristics of power transformers, we’ve prepared a series of professional articles covering selection guidelines, efficiency standards, and application insights to support project design and purchasing decisions.

Frequently Asked Questions

What is a power transformer?

A power transformer is a static piece of electrical equipment that transfers electrical energy from one circuit to another through the process of electromagnetic induction. It is most commonly used to “step-up” or “step-down” voltage levels to facilitate the efficient transmission and distribution of electricity. Because they have no moving parts, power transformers are highly efficient, reliable, and are the backbone of any AC power grid.

How does a power transformer work?

A power transformer operates on Faraday’s Law of Electromagnetic Induction. The working principle can be broken down into three steps:

  1. An alternating current (AC) flows through the primary winding, which is wrapped around a magnetic iron core. This creates a continuously changing and reversing magnetic field in the core.
  2. This changing magnetic field extends through the core and cuts through the secondary winding, which is wrapped around the same core.
  3. The moving magnetic field induces an alternating voltage in the secondary winding.

The ratio of the number of turns in the primary winding to the number of turns in the in the secondary winding determines whether the voltage is increased (stepped-up) or decreased (stepped-down).

What are the main components of a power transformer?

A typical oil-immersed power transformer is comprised of several key components:

  1. Core: Made of laminated, high-permeability silicon steel, the core provides a low-reluctance path for the magnetic flux, concentrating it and linking the primary and secondary windings.
  2. Windings: These are coils of insulated copper or aluminum conductors. The primary winding is connected to the power source, and the secondary winding is connected to the load.
  3. Insulating Oil (Transformer Oil): This mineral oil serves two primary purposes: it provides electrical insulation between the live parts and it acts as a coolant to dissipate heat.
  4. Main Tank: The steel tank that houses the core, windings, and oil.
  5. Bushings: Insulated terminals that allow the high and low voltage conductors to safely pass through the grounded steel tank.
  6. Conservator Tank: A smaller tank located above the main tank that allows the transformer oil to expand and contract with temperature changes.
  7. Radiators: A series of fins or tubes that provide a large surface area to help cool the transformer oil through natural or forced air circulation.
  8. Buchholz Relay: A gas-actuated safety device that detects faults like gas accumulation or oil surges inside the transformer and sends a trip signal.
What are the different types of power transformers?

Power transformers can be classified in several ways:

  • By Voltage Level:
    • Step-Up Transformer: Increases voltage (secondary has more turns than primary).
    • Step-Down Transformer: Decreases voltage (secondary has fewer turns than primary).
  • By Insulation Type:
    • Oil-Immersed Transformer: Uses mineral oil for insulation and cooling. The most common type for utility and industrial applications.
    • Dry-Type Transformer: Uses air and solid insulating materials instead of oil. Used where fire safety is a primary concern (e.g., inside buildings).
  • By Core Construction:
    • Core Type: Windings surround the core.
    • Shell Type: The core surrounds the windings.
  • By Phase:
    • Single-Phase Transformer: Used for single-phase power systems.
    • Three-Phase Transformer: The most common type for power transmission and distribution.
What is the difference between a step-up and a step-down transformer?

The difference lies in their winding ratio and their effect on voltage and current:

  • Step-Up Transformer: The secondary winding has more turns than the primary winding. It increases voltage from the primary to the secondary side, while proportionally decreasing the current. These are used at power plants to boost the voltage for efficient long-distance transmission.
  • Step-Down Transformer: The secondary winding has fewer turns than the primary winding. It decreases voltage from the primary to the secondary side, while proportionally increasing the current. These are used in distribution substations to reduce the voltage to a safe level for use by consumers.
Where are power transformers used?

Power transformers are ubiquitous in the electrical grid. Key applications include:

  • Generating Stations: Large Generator Step-Up (GSU) transformers increase the voltage produced by generators to transmission levels (e.g., 220kV, 400kV).
  • Transmission Substations: Used to step voltage up or down between different transmission lines.
  • Distribution Substations: Step-down transformers reduce high transmission voltage to medium voltage levels (e.g., 11kV, 33kV) for distribution to local areas.
  • Industrial Facilities: Supply power to heavy machinery and motor control centers.
  • Commercial Buildings: Power lighting, HVAC systems, and other building services.
What are power transformer losses and how can they be reduced?

Transformer losses are the reason why a transformer’s output power is slightly less than its input power. There are two main types of losses:

  1. No-Load Losses (or Core Losses): These occur in the iron core whenever the transformer is energized, even with no load connected. They are caused by the alternating magnetic flux and consist of hysteresis and eddy current losses.
  2. Load Losses (or Copper Losses / I²R Losses): These occur in the windings and are proportional to the square of the current flowing through them. They are caused by the electrical resistance of the winding conductors.

How to Reduce Losses:

  • Core Losses are reduced by using high-grade, thin laminations of silicon steel for the core.
  • Copper Losses are reduced by using properly sized copper or aluminum conductors with a larger cross-sectional area to minimize resistance.
What are the different cooling methods for power transformers?

Cooling is critical to dissipate the heat generated by losses. The cooling method is designated by a four-letter code as per IEC standards:

  • ONAN (Oil Natural Air Natural): The oil circulates naturally through the tank and radiators via convection. The surrounding air also circulates naturally over the radiators to cool them. This is the simplest method.
  • ONAF (Oil Natural Air Forced): Same as ONAN, but with electric fans blowing air across the radiators to increase the cooling rate. This allows the transformer to handle a higher load.
  • OFAF (Oil Forced Air Forced): In addition to fans, oil pumps are used to actively circulate the oil through the radiators, providing an even higher level of cooling for very large transformers.
  • OFWF (Oil Forced Water Forced): Uses oil pumps and a water-based heat exchanger to cool the oil. This is one of the most effective cooling methods.
How do you read a power transformer nameplate?

The nameplate is a vital data sheet affixed to the transformer. Key information includes:

  • Power Rating: In kVA (kilovolt-amperes) or MVA (megavolt-amperes).
  • Voltage Ratings: The rated High Voltage (HV) and Low Voltage (LV) values.
  • Number of Phases: e.g., 3-Phase.
  • Frequency: e.g., 50 Hz or 60 Hz.
  • Percent Impedance (%Z): A critical value for fault current calculations and paralleling transformers.
  • Vector Group: Describes the winding configuration and phase relationship (e.g., Dyn11).
  • Cooling Class: The cooling methods used (e.g., ONAN/ONAF).
  • Standards: The manufacturing standard it complies with (e.g., IEEE C57.12.00, IEC 60076).
Why is transformer oil testing important and what does it check for?

Transformer oil testing is a crucial part of predictive maintenance. The oil acts as a diagnostic medium, and analyzing it can reveal the internal health of the transformer without taking it out of service.

The most important test is the Dissolved Gas Analysis (DGA). Small amounts of gases dissolve in the oil during normal operation, but high levels of certain “key gases” (like acetylene, ethylene, methane) indicate specific internal faults:

  • Arcing: A severe electrical fault.
  • Corona: Partial discharge.
  • Overheating: Of the windings or core.

Other tests check the oil’s dielectric strength (its ability to insulate) and moisture content (water is highly detrimental to the insulation system).

Contact Zoliov to Start Your Cooperation Journey

As a professional power transformer manufacturer, Zoliov is committed to technological innovation and customer-focused service, providing high-quality transformer solutions and reliable technical support for global power systems. We understand the importance of every project and aim to be your most trusted long-term partner.

Whether you are a grid engineer, procurement manager, or project decision-maker, our team provides expert consultation, customized power transformer solutions, and end-to-end technical support.
Let’s work together to enhance grid efficiency and shape a smarter, more sustainable energy future.

Neutral Earthing Resistor (NER): Definition, Purpose & Applications

Join the Future of Power Distribution

Ready to Upgrade Your Electrical Infrastructure?

Don’t let outdated switchgear compromise your operations. Experience the reliability and innovation of Zoliov’s switchgear solutions—where safety meets advanced engineering.