Ring Main Unit Manufacturer

Zoliov provides reliable and high-performance ring main unit (RMU) solutions for medium voltage power distribution,industrial networks, and urban infrastructure projects worldwide. Our products ensure safety, operational continuity, and long-term system reliability in demanding environments.

What is a Ring Main Unit?

A ring main unit (RMU) is a type of medium voltage switchgear used to control, protect, and sectionalize power distribution networks, typically operating between 11 kV and 36 kV. It plays a key role in ensuring continuous power supply, enabling flexible network configuration, and providing reliable protection for underground and urban power distribution systems.

Main application scenarios

  • Urban distribution networks – ensuring stable and safe power supply for cities

  • Industrial power systems – providing reliable distribution and protection for factories

  • Renewable energy integration – connecting distributed generation to medium voltage grids

  • Commercial buildings and complexes – supporting efficient and flexible power management

  • Underground cable networks – improving network reliability and fault isolation

Ring main units are essential for continuous power supply, network flexibility, and fault protection in modern medium voltage distribution systems, especially in dense urban and industrial environments.

Ring Main Unit

Zoliov — Your Reliable Ring Main Unit Manufacturer

point one

Strong Technical Expertise

With over 20 years of professional manufacturing experience, Zoliov has built deep expertise in ring main unit technologies. We provide complete RMU solutions for various medium voltage distribution networks, supported by a dedicated R&D team that continually innovates to deliver safe, efficient, and reliable equipment.

point two

Strict Quality Assurance System

Our production is certified to ISO9001 and ISO14001 standards and fully complies with IEC and GB regulations. Every ring main unit undergoes rigorous type testing and inspection to ensure excellent performance, safety, and long service life under real-world operating conditions.

point three

Customized Engineering Services

We offer tailored RMU design solutions to meet each project’s technical requirements and site conditions. From system planning and engineering to installation and commissioning, Zoliov provides end-to-end technical support for complex power distribution projects worldwide.

FEATURED PRODUCTS

Featured Ring Main Unit Products

Explore Zoliov’s comprehensive range of ring main units (RMUs), designed for medium voltage distribution networks that demand safety, reliability, and operational flexibility.
All products can be custom-engineered to meet specific technical parameters and project requirements, ensuring optimal performance in diverse applications.
We provide one-stop services — from product design and manufacturing to on-site installation and commissioning — to guarantee smooth project execution and long-term system stability.

GTXGN-12 Solid Insulated Ring Main Unit
GTXGN-12 Solid Insulated Ring Main Unit

Ring Main Unit GTXGN-12 Solid Insulated Ring Main Unit The GTXGN-12 Solid Insulated Ring Main...

Outdoor Ring Main Unit (RMU)
Outdoor Ring Main Unit (RMU)

High Voltage Cable Branch Box Outdoor Ring Main Unit (RMU) The Outdoor Ring Main Unit...

XGN-12 environmentally friendly Ring Main Unit
XGN-12 environmentally friendly Ring Main Unit

Ring Main Unit XGN-12 environmentally friendly Ring Main Unit The XGN-12 environmentally friendly Ring Main...

SRM16-12 SF6 Gas-Insulated Ring Main Unit
SRM16-12 SF6 Gas-Insulated Ring Main Unit

Ring Main Unit SRM16-12 SF6 Gas-Insulated Ring Main Unit The SRM16-12 is a fully insulated...

GTXGN-12 Solid Insulated Ring Main Unit
HXGN-12 box-type fixed metal-enclosed ring main unit switchgear

Ring Main Unit HXGN-12 box-type fixed metal-enclosed ring main unit switchgear The HXGN-12 box-type fixed...

Why Choose Zoliov as Your Ring Main Unit Manufacturer?

Advanced Manufacturing Capacity

Zoliov operates a modern production facility equipped with advanced international equipment and automated processes. With an annual capacity of over 1,000 sets of ring main units, we can support large-scale engineering projects while ensuring consistent product quality and reliable delivery schedules.

Authoritative Certifications

Our production is certified to ISO9001 and ISO14001 standards and fully complies with IEC and GB regulations. Every ring main unit undergoes rigorous type testing and inspection to ensure excellent performance, safety, and long service life under real-world operating conditions.

Comprehensive Technical Support

Our experienced engineering team provides end-to-end technical support, including system planning, product selection, installation, and commissioning. With 24/7 assistance and rapid response times, we ensure seamless project execution and long-term operational stability.

Global Projects

America, Nevada, PV project

China, Beijing Daxing Airport

Vietnam, Hanoi,Biopharmaceutical Plant

Power distribution system for enterprises in the Philippines

Brazil, wind-solar hybrid complex

UAE, Shams Power Plant Project

Zimbabwe, 132KV transmission and distribution system

Malaysia, Penang, Semiconductor Industrial Zone

CUSTOMIZED SERVICE STEPS

Customer request
Submit parameters and drawings
Determine parameters and drawings
Offer according to drawings
Sign contract
Material procurement and production
Test and quality inspection
Inspection and delivery

Ring Main Unit Technical Resources

To help engineers and procurement decision-makers better understand the technical characteristics of ring main units, we’ve compiled a series of professional articles covering selection guidelines, technical comparisons, and key application insights to support your project design and purchasing decisions.

Frequently Asked Questions

What is a ring main unit?

A Ring Main Unit (RMU) is a factory-assembled, metal-enclosed, and compact set of switchgear used in medium voltage (MV) secondary distribution networks. Its primary function is to supply power to one or more distribution transformers from a ring-configured electrical grid. A typical RMU includes two incoming load break switches for the “ring” connections and one or more feeder units with either a fuse-switch or a circuit breaker to protect the transformer. They are often sealed-for-life units, using an insulating medium like SF6 gas or a solid dielectric, which makes them extremely reliable and virtually maintenance-free.

How does a ring main unit work?

A Ring Main Unit (RMU) operates as a key node in an electrical ring network, which provides enhanced power reliability. Here’s the working principle:

  1. Ring Network Connection: An RMU is connected to a medium voltage ring circuit. This means it receives power from two directions. Two dedicated switches within the RMU, called Load Break Switches (LBS) or Ring Switches, connect to the incoming and outgoing cables of this ring.
  2. Normal Operation: During normal operation, both ring switches are closed, allowing power to flow through the RMU to the next point in the loop. The RMU “taps off” a portion of this power to feed a local distribution transformer.
  3. Transformer Protection: This “tap-off” is managed by a Feeder Unit. This unit can be a switch-fuse combination or a vacuum circuit breaker (VCB). Its job is to protect the transformer from overloads and short circuits. If a fault occurs on the transformer side, this feeder unit will automatically trip, disconnecting only that transformer without interrupting the main ring.
  4. Fault Isolation: If a fault occurs somewhere on the main ring cable, operators can go to the RMUs on either side of the fault and open their respective ring switches. This isolates the faulty section of the cable. Because power can be supplied from the other direction of the ring, service can be quickly restored to all customers except those on the isolated segment, significantly reducing outage times.
Ring main unit vs. switchgear

While an RMU is a type of switchgear, the term “switchgear” typically refers to more conventional, modular assemblies. Here are the key differences:

Feature Ring Main Unit (RMU) Conventional MV Switchgear (e.g., AIS/GIS Panels)
Structure Compact, integrated, often a single sealed tank. Modular, consisting of individual functional panels bolted together.
Application Secondary distribution (e.g., feeding transformers). Primary distribution, main substations, and large industrial feeders.
Extensibility Limited or non-extensible. Highly extensible; new panels can be easily added.
Footprint Very small and compact. Large, requires a dedicated switchgear room.
Maintenance Virtually maintenance-free (“sealed for life”). Requires periodic maintenance (cleaning, testing, lubrication).
Configuration Fixed, standardized configurations (e.g., 2 LBS + 1 Feeder). Highly customizable configurations for complex schemes.
Environment Sealed design makes it immune to harsh environmental conditions. Can be sensitive to dust, moisture, and altitude unless specifically designed.
Applications of ring main unit in power distribution

RMUs are essential components in modern power distribution networks due to their compactness and reliability. Key applications include:

  • Compact Secondary Substations (CSS): RMUs are the core component inside packaged or kiosk substations that transform medium voltage to low voltage for residential and commercial areas.
  • Wind and Solar Power Farms: Used to collect power from multiple wind turbines or solar inverter stations and connect them to the grid. Their sealed design is ideal for harsh outdoor environments.
  • Industrial Facilities: For distributing power within large industrial plants to various load centers.
  • Commercial and Residential Complexes: In large buildings like airports, hospitals, data centers, and shopping malls, RMUs are used for the internal medium-voltage distribution ring.
  • Underground Distribution: Their compact size makes them perfect for installation in underground vaults in dense urban areas.
Specifications for electrical ring main unit system

When specifying an RMU for a project, the following technical data is required:

  • Rated Voltage (kV): The system voltage it is designed for (e.g., 12kV, 24kV, 36kV).
  • Rated Current (A): The continuous current the ring switches and feeder can carry (e.g., 630A).
  • Insulation Medium: The substance used for insulation and arc quenching (e.g., SF6 gas, Dry Air, Solid Dielectric).
  • Rated Frequency (Hz): The system frequency (e.g., 50Hz or 60Hz).
  • Short-Circuit Breaking Current (kA): The maximum fault current the circuit breaker feeder can safely interrupt.
  • Short-Time Withstand Current (kA/s): The fault current the unit can withstand for a specified duration (typically 1 or 3 seconds).
  • Configuration: The number and type of functional units (e.g., “2+1” meaning two ring switches and one feeder).
  • Protection Type: The device used on the feeder (e.g., Fuse with switch-disconnector, or Vacuum Circuit Breaker with relay).
  • Standards Compliance: Conformance to standards like IEC 62271-200.
Ring main unit explained simply

Imagine your neighborhood’s power is delivered through a large loop, or a “ring.” A Ring Main Unit (RMU) is like a smart, sealed, and very tough electrical junction box placed along this loop.

It has three main jobs:

  1. Two switches act like gates to let the power continue flowing through the loop to your neighbors.
  2. A third switch, with a built-in fuse or circuit breaker, taps into that power to safely feed the green transformer box that serves your street.
  3. If there’s a problem with the cable somewhere in the loop, the power company can go to an RMU and simply close one gate and open another to reroute the power, keeping everyone’s lights on while they fix the problem.

Because it’s completely sealed, it’s very safe and doesn’t require much upkeep, making it perfect for placing around towns and cities.

Types of ring main units

RMUs can be categorized in several ways:

  1. By Insulation Medium:
    • SF6 Gas Insulated: The most common type, offering excellent insulation in a very compact size.
    • Air Insulated (AIS RMU): Uses air as the primary insulation. It is environmentally friendly but larger than SF6 units.
    • Solid Insulated / Dry Air Insulated: Newer “green” technologies that use solid epoxy resin and/or treated air for insulation, avoiding the use of SF6 gas.
  2. By Extensibility:
    • Non-Extensible RMU: A single, sealed unit with a fixed configuration that cannot be added to later.
    • Extensible RMU: Designed in a modular way, allowing additional functional units (like more feeders) to be added to one or both sides in the future.
  3. By Feeder Protection:
    • Fused RMU: Uses a high-voltage fuse combined with a switch for transformer protection. Cost-effective but requires fuse replacement after a fault.
    • Circuit Breaker RMU: Uses a vacuum circuit breaker (VCB) with a protective relay. It is resettable, more versatile, and offers more advanced protection.
Safety precautions for ring main unit operation

Operating an RMU involves handling medium voltage and must only be done by trained and authorized personnel.

  • ✅ Verify Authorization: Ensure you are qualified and authorized to operate the equipment.
  • ✅ Wear Proper PPE: Always wear appropriate Personal Protective Equipment, including a helmet with face shield, insulated gloves, and arc-flash-rated clothing.
  • ✅ Use Voltage Detectors: Before any operation, use an approved MV voltage detection device to confirm if circuits are live or de-energized.
  • ✅ Follow LOTO: Implement Lockout-Tagout procedures when isolating equipment for maintenance.
  • ✅ Check Gas Pressure: For SF6 RMUs, always check the pressure gauge before operation. Do not operate if the pressure is in the red “alarm” zone.
  • ✅ Respect Interlocks: Never attempt to defeat or force mechanical or electrical interlocks. They are there to prevent dangerous operations.
  • ✅ Operate Firmly: Operate switches with a firm, confident, and swift motion as instructed by the manufacturer to ensure proper contact and arc quenching.
  • ✅ Apply Earthing Switches: After confirming a circuit is de-energized, always apply the earthing switch for safety before starting work.
What is the main advantage of an RMU's compact size?

Its small footprint allows for installation in tight spaces like basements of buildings, underground vaults, and compact substations, saving valuable real estate in urban areas.

How does an RMU improve power reliability?

By enabling a ring network topology, it allows for fast fault isolation and power restoration. Outages can be limited to very small areas, improving grid performance metrics like SAIDI and SAIFI.

Contact Zoliov to Start Your Cooperation Journey

As a professional ring main unit manufacturer, Zoliov is committed to technological innovation and customer-oriented service, delivering high-quality RMU solutions and reliable support for global medium voltage distribution projects. We understand the importance of each engineering project and strive to be your most trusted long-term partner.

Whether you are a substation engineer, procurement manager, or project decision-maker, our team provides professional consultation, customized RMU solutions, and comprehensive technical support from design to commissioning.
Let’s work together to improve power distribution reliability and drive the advancement of modern electrical networks.

Neutral Earthing Resistor (NER): Definition, Purpose & Applications

Join the Future of Power Distribution

Ready to Upgrade Your Electrical Infrastructure?

Don’t let outdated switchgear compromise your operations. Experience the reliability and innovation of Zoliov’s switchgear solutions—where safety meets advanced engineering.