10kV SC(B)10/11/12/13/14/18 series dry-type epoxy resin cast transformers

11KV level dry-type transformer

Safe 11kV dry-type transformer for indoor distribution, fire resistance, low noise, and low maintenance.

11KV level dry-type transformer

11KV level dry-type transformer

The 11KV level dry-type transformer are designed as an advanced replacement for traditional oil-immersed distribution transformers. These power transformers excel in performance and are ideal for urban grids, high-rise buildings, commercial centers, theaters, hospitals, hotels, tunnels, subways, stations, docks, airports, underground power stations, laboratories, and modular power substations.

11KV level dry-type transformer

Key Features:

The 11kV epoxy resin cast dry-type transformer is manufactured using vacuum epoxy resin casting technology. It is fire-resistant, flame-retardant, explosion-proof, and pollution-free, making it suitable for direct installation in indoor areas, basements, densely populated places, and other environments with high safety requirements. With high mechanical strength, strong short-circuit resistance, moisture and dust resistance, simple maintenance, low noise, and long service life, it is a safe, environmentally friendly, and reliable distribution transformer.

11KV level dry-type transformer

Why choose a 11KV dry-type transformer

These electrical transformers are designed with advanced materials, scientific formulations, and rigorous testing, ensuring superior durability, reliability, and operational safety. The windings have excellent heat dissipation, supported by air natural cooling (AN) and optional air-forced cooling (AF) systems, enabling short-term overload capacity for safe operation. Additionally, their decentralized installation near load centers minimizes line costs and eliminates the need for costly fireproof systems or backup power sources.

Product Advantages
High Mechanical Strength: The high-voltage windings use copper wire, while low-voltage windings utilize copper wire or foil, vacuum cast with filler-free epoxy resin for a robust, tubular structure. This design ensures high mechanical strength, minimal partial discharge, and reliable performance.
Eco-Friendly and Safe: The transformer is flame-retardant, explosion-proof, and environmentally friendly. Glass fiber insulation materials have self-extinguishing properties, and the resin does not emit harmful gases under high heat.
Durable and Weather-Resistant: Moisture-resistant coils and specially protected iron core components allow the transformer to operate in 100% humidity and harsh environments without dehumidification during intermittent use.
Energy-Efficient and Compact: With low losses, high economic efficiency, and minimal maintenance, it features a compact design, reduced weight, and smaller footprint, making installation cost-effective.
Operating Conditions
Ambient Temperature: -25°C to +40°C.
Relative Humidity: Daily average ≤95%, monthly average ≤90%.
Altitude: ≤1,000 meters.
Installation: Suitable for environments free of fire hazards, explosion risks, or intense vibrations.

Application

The 11kV epoxy resin cast dry-type transformer features fireproof, flame-retardant, safe and environmentally friendly properties, as well as moisture-proof and dust-proof capabilities. It is mainly applicable to indoor areas with strict requirements for fire protection and safety, and is widely used in high-rise buildings, shopping malls, hospitals, schools, data centers, subways, airports, power plants, industrial and mining enterprises, and densely populated areas. It can be directly installed close to the load center, ensuring safe and reliable operation.

Model meaning
SCB10-XXX/11 S: Three-phase dry-type transformer
C: Epoxy resin encapsulated insulation
B: Foil winding, strong overload resistance
10: Performance loss level, higher number means more energy-saving
XXX: Rated capacity (kVA)
11: Rated voltage 11kV (high-voltage side)
Technical Parameters
Item Specification
Rated Voltage HV: 11 kV; LV: 0.4 kV
Rated Capacity 100–2500 kVA (standard: 400 / 500 / 630 / 800 / 1000 / 1250 / 1600 kVA)
Number of Phases / Frequency Three-phase, 50 Hz
Vector Group Dyn11
Insulation Type Epoxy resin vacuum cast
Cooling Method AN (Air Natural) / AF (Air Forced)
Tap Changer Off-circuit tap changer: ±2 × 2.5%
Impedance Voltage 4%–6%
Winding Material Copper winding (SCB series uses foil winding)
Insulation Class Class F or Class H
Degree of Protection IP20 / IP23 / IP30 / IP31
Operating Environment Indoor use, moisture-proof, dust-proof, flame-retardant, fire-resistant
Performance Level SCB10, SCB13, SCB14 (low-loss types)
Overall and mounting dimensions(mm)(Reference)

The overall dimensions of the dry-type transformer housing

Custom 11kV Epoxy Resin Cast Dry-Type Transformer Solutions

Custom 11kV Epoxy Resin Cast Dry-Type Transformer Solutions

(The values can be customized according to project requirements.)

If you have specific requirements for the parameters, structure, or configuration of the 11kV dry-type transformer, please contact us. Our team of account managers, technical engineers, and product consultants will assess your electrical system design and provide a tailored solution.

We can customize rated capacity, voltage class, winding arrangement, insulation level, connection configuration, cooling method, and enclosure protection grade to ensure reliable performance and efficient operation in your medium-voltage distribution system.

The 11kV epoxy resin cast dry-type transformer features excellent insulation performance, low noise, low loss, and maintenance-free operation, making it ideal for industrial plants, commercial facilities, high-rise buildings, data centers, renewable energy systems, and critical infrastructure applications.

By tailoring transformer specifications to your project’s specific electrical requirements and operating conditions, you ensure stable power distribution, improved energy efficiency, enhanced safety, and long-term reliability in your power network.

FAQ

What is a dry‑type epoxy resin cast transformer?

A dry‑type epoxy resin cast transformer is a transformer where the core and windings are encapsulated in epoxy resin, eliminating the need for oil. It uses air cooling and is designed for safe, environmentally friendly indoor power distribution.

What do the SCB10/11/12/13/14/18 series represent?

These series identifiers (SCB10, SCB11, SCB12, SCB13, SCB14, SCB18) refer to different design standards, insulation systems, and manufacturing improvements within the 11kV dry‑type epoxy resin transformer family.

What does “11kV” mean?

“11kV” refers to the primary rated voltage of the transformer. These units are engineered to operate in medium voltage distribution networks (up to 10,000 volts) to step down power for downstream loads.

What are the advantages of epoxy resin cast transformers?

Epoxy resin cast transformers offer:
• Excellent insulation and moisture resistance
• No oil, reducing fire hazards and environmental risk
• High mechanical strength
• Low maintenance requirements
• Suitable for indoor or semi‑open environments

Where are these transformers commonly used?

Typical applications include industrial plants, commercial facilities, residential power distribution rooms, hospitals, airports, data centers, and shopping malls where safety and low maintenance are important.

How does a dry‑type transformer dissipate heat?

These transformers rely on natural air circulation and the high thermal conductivity of epoxy resin to dissipate heat, maintaining temperature stability without oil.

What are typical insulation classes for dry‑type epoxy transformers?

Common insulation classes include Class F (155°C) and Class H (180°C). These indicate the transformer’s capability to withstand higher temperatures during operation.

Are dry‑type epoxy transformers safer than oil‑immersed ones?

Yes. Because they do not contain combustible oil, dry‑type epoxy resin transformers are safer for indoor and heavily populated locations. They also reduce fire risk and simplify regulatory compliance.

What maintenance do these transformers require?

Routine checks typically include:
• Visual inspection for dust/debris
• Checking connection tightness
• Monitoring temperature and ventilation
• Ensuring no obstruction to airflow

Dry‑type epoxy units generally require less maintenance than oil‑immersed types.

Can these transformers be customized?

Yes. They can be tailored by:
• Adjusting capacity (kVA/MVA)
• Changing voltage ratios
• Adding monitoring or protection modules
• Adapting cooling schemes or enclosure types
to suit specific project requirements.

Related products

Check out these related products you might also be interested in.

Electric power fittings 4

Electric Power Fittings

Zoliov provides electric power fittings, power line fittings, overhead line fittings, and pole line hardware for transmission lines, distribution lines, substations, and power grid projects.

Read More »

Related articles

Get in Touch

Have questions or concerns about electrical power distribution products? Get answers quickly by emailing our engineers.

Nearly 20 Years of Industry Experience
10,000+ Units/Year Production Capacity
40,000m²+ Factory Area
500+ Power Utility Clients
1 Billion+ CNY Annual Sales Revenue

Get A Free Quote Now !

If you have any questions, please do not hesitate to contact us.

Company of Zoliov