GTXGN-12 Solid Insulated Ring Main Unit
Ring Main Unit GTXGN-12 Solid Insulated Ring Main Unit The GTXGN-12 Solid Insulated Ring Main Unit (RMU) is an innovative, environmentally friendly, and fully sealed
The MNS low-voltage withdrawable switchgear is a modular cabinet type assembled in the factory (FBA) using standard modules. This series is designed for use in power plants, substations, petrochemical, metallurgy, transportation energy, light industry and textile enterprises, as well as residential areas and high-rise buildings. It serves as a distribution device for power conversion, distribution, and control in electrical systems operating at an AC frequency of 50-60Hz and a rated voltage of 660V and below.
The MNS low-voltage switch cabinet is mainly used in industrial and mining enterprises, buildings, power plants, and various engineering projects. It serves as the core equipment for power distribution, motor control, and power allocation in the 50/60Hz AC low-voltage system.
| MNS low-voltage withdrawable switchgear | M: | Modular structure |
| N: | Low-voltage | |
| S: | Switchgear |
The MNS low-voltage withdrawable switchgear is designed for 400V/690V AC low-voltage distribution systems and supports main busbar ratings from 630A to 6300A. It provides flexible drawer and fixed unit configurations, protection levels from IP30 to IP54, and compliance with IEC 61439 and GB/T 7251.1/12, making it suitable for power distribution, motor control, and low-voltage power management in industrial and commercial projects.
| Category | Parameter | Standard Range / Specification | Remarks |
|---|---|---|---|
| Electrical System | Rated Operational Voltage (Ue) | 400V / 690V AC | Compatible with mainstream low-voltage systems |
| Rated Insulation Voltage (Ui) | ≤1000V AC | Ensures sufficient insulation margin | |
| Rated Impulse Withstand Voltage (Uimp) | 8kV | Overvoltage Category III | |
| Rated Frequency | 50/60Hz | Suitable for global applications | |
| Main Busbar | Rated Current | 630A–6300A | Maximum value for horizontal busbar |
| Rated Short-Time Withstand Current (Icw) | 50 / 80 / 100kA (1s) | Thermal and dynamic stability capability | |
| Rated Peak Withstand Current (Ipk) | 105 / 176 / 220kA | Withstands short-circuit impact current | |
| Distribution / Branch Busbar | Rated Current | 400A–1600A | For vertical / branch circuits |
| Rated Short-Time Withstand Current (Icw) | 30kA–80kA (1s) | Suitable for branch circuit capacity | |
| Rated Peak Withstand Current (Ipk) | 63kA–143kA | Branch circuit impact withstand capability | |
| Structure & Protection | Cabinet Height | 2200mm | Standard height |
| Cabinet Width | 400 / 600 / 800 / 1000 / 1200mm | Modular combination | |
| Cabinet Depth | 800 / 1000mm | Can be arranged in back-to-back installation | |
| Degree of Protection (IP) | IP30–IP54 | Standard IP40, customizable | |
| Drawer Unit Specification | 8E/4, 8E/2, 8E, 16E, 24E | Up to 36 circuits per cabinet | |
| Mechanical Life of Drawer Unit | ≥2000 operations | Reliable plug-in and withdrawal performance | |
| Environment & Standards | Ambient Temperature | -5°C to +40°C | 24-hour average ≤35°C |
| Relative Humidity | ≤50% (at 40°C) | Short-term condensation allowed | |
| Altitude | ≤2000m | Customizable for higher altitude | |
| Standards | IEC 61439, GB/T 7251.1/12 | Complies with both international and domestic standards |
Custom MNS Switchgear Solutions for Your Project
(The values can be customized according to local project requirements.)
If you have specific requirements for the parameters, structure, or configuration of the MNS low-voltage withdrawable switchgear, please contact us. Our team of account managers, technical engineers, and product consultants will evaluate your application scenario, electrical parameters, protection requirements, installation conditions, and project schedule to develop a suitable solution.
We can help customize rated voltage, current range, cabinet layout, drawer or fixed functional units, protection level, and other design details to match your distribution system and operating environment.
There are five standard drawer sizes, all based on the height module of 8E (200 mm):
These five drawer unit types can be assembled individually in one cabinet or combined in a mixed arrangement.
The standard unit sizes are also based on the height module of 8E (200 mm):
Each unit can be assembled individually in one cabinet or in a mixed arrangement.
MNS switchgear is commonly used for power distribution, motor control, reactive power compensation, and centralized low-voltage control in industries such as power generation, petrochemical, metallurgy, transportation, manufacturing, and building infrastructure.
Withdrawable switchgear uses drawer-type functional units that can be quickly removed for maintenance or replacement, reducing downtime. Fixed switchgear uses permanently installed units and is often chosen for simpler distribution tasks or lower-cost projects.
The standard rated operational voltage of MNS low-voltage withdrawable switchgear is typically 400V or 690V AC, with a rated insulation voltage up to 1000V AC.
The main busbar rated current of MNS switchgear generally ranges from 630A to 6300A, depending on the project design and cabinet configuration.
MNS low-voltage withdrawable switchgear is commonly designed to comply with IEC 61439 and GB/T 7251.1/12, helping ensure safety, performance, and reliability for low-voltage switchgear assemblies.
The cabinet protection degree typically ranges from IP30 to IP54. IP40 is often used as a standard option, while higher protection levels can be customized based on installation conditions.
The withdrawable drawer structure allows operators to inspect, replace, or service functional units more quickly than fixed-mounted systems. This helps reduce maintenance time and improves operational continuity.
Yes. MNS switchgear is widely used in MCC systems because its modular structure supports flexible motor feeder arrangements, easy maintenance, and safe separation between functional units.
Yes. MNS switchgear can be customized based on project requirements such as rated current, cabinet dimensions, protection degree, circuit arrangement, application environment, and special installation conditions.
Check out these related products you might also be interested in.
Ring Main Unit GTXGN-12 Solid Insulated Ring Main Unit The GTXGN-12 Solid Insulated Ring Main Unit (RMU) is an innovative, environmentally friendly, and fully sealed
Electrical components Medium-voltage electrical components Medium voltage electrical components are essential in power systems, designed to handle and transmit medium voltage efficiently. They ensure the
Electrical components Low-voltage electrical components Low-voltage electrical components are essential devices used in circuits with voltages below 1200V (AC) or 1500V (DC). These include circuit
Zoliov provides electric power fittings, power line fittings, overhead line fittings, and pole line hardware for transmission lines, distribution lines, substations, and power grid projects.
You need electrical equipment to help data centers work well. Good systems stop outages, which can cost a lot of money. Power problems are the
You will see many important types of electrical equipment in electric vehicle charging stations, which are a crucial part of the charging infrastructure. These include
Electrical equipment plays a key role in ensuring that new energy projects operate effectively. Electrical engineers and electricians are essential in maintaining the safety and
You have an important job when you pick the Efficient switchgear for your building, especially considering the role of power distribution. The world market for
Have questions or concerns about electrical power distribution products? Get answers quickly by emailing our engineers.
WhatsApp us